Skip to main content

Table 3 Composite measure score calculations based on patient scenarios

From: Development of a percutaneous coronary intervention patient level composite measure for a clinical quality registry

 

Patient 1 had an uneventful post-PCI recovery period,

and scored a PROM of 2.

Patient 2 developed a new stent thrombosis on Day 17 post-PCI. Nevertheless, Patient 2 felt unwell in the 7 days leading up to the 30 day post PCI call and scored a low PROM of 7.

Patient 4 had a new myocardial infarction on Day 17 post-PCI and died on day 20 post-PCI

Individual composite measure and (%) weighting

Status

Calculations

Status

Calculations

Status

Calculations

New heart failure within 30 days post-PCI (7)

No (1)

7 × 1 = 7

No (1)

7 × 1 = 7

No (1)

7 × 1 = 7

New myocardial infarction within 30 days post-PCI (19)

No (1)

19 × 1 = 19

Yes (0)

19 × 1 = 19

Yes (0)

19 × 0 = 0

New stent thrombosis within 30 days post-PCI (23)

No (1)

23 × 1 = 23

Yes (0)

23 × 0 = 0

No (1)

23 × 1 = 23

Major bleeding event within 30 days post-PCI (12)

No (1)

12 × 1 = 12

No (1)

12 × 1 = 12

No (1)

12 × 1 = 12

New stroke within 30 days post-PCI (16)

No (1)

16 × 1 = 16

No (1)

16 × 1 = 16

No (1)

16 × 1 = 16

Unplanned cardiac rehospitalisation within 30 days post-PCI (13)

No (1)

13 × 1 = 13

No (1)

13 × 1 = 13

No (1)

13 × 1 = 13

Overall PROM score (10)

2

10–2 = 8

7

10–7 = 3

Cannot be administered

Composite measure score (out of 100)

 

98

 

70

 

N/A